Long-Term Clinical Outcomes of V4c ICL Implantation Using Swept-Source Anterior Segment OCT for Pre-Operative Internal Measurement | ASCRS
Presentation
Long-Term Clinical Outcomes of V4c ICL Implantation Using Swept-Source Anterior Segment OCT for Pre-Operative Internal Measurement
May 2020
Meeting: 2020 Virtual Annual Meeting
Session: SPS-104 Refractive Procedure Outcomes: SMILE, SMILE & CXL, ICL
Author: Sung Min Kim, MD
This content is only available for ASCRS Members

This content from the 2020 ASCRS Virtual Annual Meeting is only available to ASCRS members. To log in, click the teal "Login" button in the upper right-hand corner of this page.

Purpose
To assess long-term clinical outcomes of Visian implantable collamer lens(ICL) V4c implantation based on internal measurement using swept-source Fourier-domain anterior segment optical coherence tomography(AS-OCT).

Methods
Patients who underwent V4c ICL implantation from June, 2018 to December, 2018 and completed 6 month follow-up in Nunemiso Eye Clinic have been collected. Six-month clinical outcomes of 388 eyes of 195 subjects were analyzed. ICL size for implantation was determined by internal measurement using swept-source AS-OCT(CASIA2). Anterior chamber values with other modalities including Pentacam HR, Gallilei G4 and IOL master 500 were also measured pre-operatively and compared with that of CASIA2.

Results
Mean pre-operative myopia, astigmatism and axial length for the study group was -7.2±2.7D, -1.6±1.0D and 26.58±1.17mm, respectively. Mean post-operative ICL vaulting at 6-month post-op. was 519.0±159.9um. Considering the stable vaulting range from 250um to 750um, percentage of the low vault was 4.4%(17 eyes) and high vault was 5.7%(22 eyes). ICL exchange was done in 2 cases(0.51%) due to excessively low(<150um) or high(>1000um) vault. Angle-to-angle measurement by CASIA2 was not significantly different with white-to-white(WTW) measurement by Pentacam HR. However, it showed significant differences with WTW values by Gallilei G4 or IOL master 500(p<0.05).

Conclusion
High accuracy for the stable lens vaulting would be expected with swept-source AS-OCT based ICL implantation. Also, pre-op. analysis of anterior chamber values by CASIA2 could reduce complications and re-operation rates. Thus, high-resolution, fast scanning nature of CASIA2 offers predictable and safe results for the ICL surgery with convenience.